Diamond Logo
Contact Us
Roche Cobas C701 Chemistry Analyzer
Roche Cobas C701 Chemistry Analyzer

Roche Cobas C701 Chemistry Analyzer

Item# 0-RO-8000C701-ER

The Roche Cobas C701 Chemistry Analyzer, provided by Roche Diagnostics

Equipment SupportService OptionsService OptionsConsumablesConsumablesQuality ControlsQuality ControlsService PartsService Parts

Package Size: EA



SmartLyte Plus

Refurbished Roche cobas c701 Chemistry Analyzer The high-volume chemistry module of the Roche cobas 8000, rebuilt Down-To-Frame® to original specification. You save up to 70% compared with buying new, and you can finance with $0 down. The Roche cobas c701 module runs up to 2,000 photometric tests an hour on a cobas 8000, with 70 reagent positions and RFID-tracked reagents. Roche built it with the same functions and throughput as the cobas c702, minus the c702's reagent manager. Buy it refurbished from Diamond and allocate more budget to other priorities. Save up to 70% compared with a new cobas c 701 module, for the same throughput as a c702. Run up to 2,000 tests an hour from one module, enough to carry a core lab's routine chemistry. Keep 70 reagent positions on board for a broad routine menu. Finance up to $2 million with $0 down, and roll shipping into the payments. Every module is rebuilt Down-To-Frame® by an FDA-registered, ISO 13485:2016 certified refurbisher, then validated with multi-level QC. Our engineers install it on your cobas 8000, verify your assays and service it afterward. REQUEST A QUOTE Refurbished Roche cobas c701 Chemistry Analyzer installed in a laboratory by a Diamond field engineer How the cobas c701 carries a high-volume chemistry load The c701 is a high-throughput photometric module for the cobas 8000. The core unit sends it racks, its own module sample buffer holds them, and it returns racks to the core unit when testing is done. Built for volume Up to 2,000 tests an hour. One c701 can carry a core lab's routine chemistry: metabolic panels, liver and renal tests, lipids and enzymes. Module sample buffer. Racks wait in the c701's own buffer, so it samples in random order and never waits on another module. About 5.5 µL per test on average. Low sample use leaves volume for reruns and add-on orders, which matters when the same tube feeds several modules. Reagents 70 reagent positions. Room for a broad routine menu, with duplicate positions for your highest-volume tests. RFID-tagged cassettes. The module reads each cassette's identity and data automatically. Liquid level and foam detection on reagents. The module checks reagent volume and catches foam before it affects a result. Result integrity Serum indices on every sample. Lipemia, hemolysis and icterus are measured and flagged. Clot and liquid level detection on samples. Clots get caught before they produce a bad result or block a probe. Ultrasonic mixing. Nothing touches the reaction mix, so there's no stirrer carryover. Automatic rerun and dilution. Out-of-range results rerun without a tech pulling the tube. Electrolytes run on the cobas 8000 ISE module, at 900 tests an hour on the Core ISE or 1,800 on the Core Dual ISE. A busy c701 line can send more samples for electrolytes than a single ISE unit's 300 an hour, which makes the dual ISE the better match. The cobas c701 test menu The c701 runs Roche's cobas c photometric menu for serum, plasma, urine, CSF and hemolysate. In most labs it carries the high-volume routine work: Metabolic and renal. Glucose, BUN, creatinine, calcium, magnesium, phosphorus, uric acid and bicarbonate. Liver. ALT, AST, ALP, GGT, bilirubin, albumin and total protein. Lipids and cardiac. Cholesterol, HDL, LDL, triglycerides, CK and LDH. Pancreas and inflammation. Amylase, lipase and CRP. Specific proteins, drugs and toxicology as your volume calls for. Roche's cobas 8000 specifications don't list whole blood for the c701, so whole-blood HbA1c goes on a cobas c502 on the same line. Send your menu with your quote request and we'll confirm what runs on the module you're buying. cobas 8000 configurations with the c701 A cobas 8000 pairs one core unit with up to four analytical modules, plus an optional ISE module. Builds with the c701 include: ISE + c701. A chemistry and electrolyte line for a large hospital or reference lab, at up to 2,000 photometric tests an hour. ISE + c701 + c502. The c701 carries routine chemistry and the c502 handles HbA1c, specific proteins and drugs. ISE + two c701 modules. Up to 4,000 photometric tests an hour, with a second module that keeps the menu running during maintenance. ISE + c701 + immunoassay. Add an e 602 or e 801 module and run chemistry and immunoassays from one rack. Roche cobas c701 Chemistry Analyzer configurations Planning your site for a cobas c701 Floor space. The c701 with its module sample buffer measures 150 x 114 x 135 cm (59 x 45 x 53 in, W x D x H). Add it to the length of the line, plus service clearance. Floor load. It weighs 697 kg (1,537 lb). Check floor ratings along the delivery path and at the install spot. Power. 200, 208, 220 or 230 V AC at 50 or 60 Hz, rated 3 kVA, with an actual maximum draw of 2.3 kVA. Heat. Rated at 10,800 kJ an hour, with an actual maximum of 8,280 kJ an hour. Share this with facilities so the room's HVAC can carry it. Water and drain. The module draws on the system's deionized water supply and drain. Roche's spec sheet lists about 50 L an hour for a c701 with an ISE module, so size your water system for it. Dimensions (W x D x H)150 x 114 x 135 cm (59 x 45 x 53 in) Weight697 kg (1,537 lb) Power200/208/220/230 V AC, 50/60 Hz; 3 kVA rated, 2.3 kVA actual maximum Heat output10,800 kJ/hour rated, 8,280 kJ/hour actual maximum WaterAbout 50 L/hour with an ISE module, per Roche's spec sheet Who buys a refurbished Roche cobas c701 Large hospital core labs. A c701 carries thousands of routine chemistry tests a day on a single module. Reference and commercial labs. Two c701 modules on one line deliver up to 4,000 photometric tests an hour with built-in redundancy. Labs already running a cobas 8000. A refurbished c701 adds capacity, replaces a failing module or gives a second high-volume module for backup, at a fraction of new-module cost. Labs that prefer to manage reagents themselves. If your reagent use is predictable and you don't need the c702's automatic decapping, the c701 delivers the same throughput. What goes into a refurbished cobas c701 quote A refurbished cobas c701 from Diamond costs up to 70% less than a new module. There's no single list price, because your quote depends on: Module or full line. A c701 for your existing cobas 8000, or a full system with core unit and ISE module. Build year and software. The module's age and the cobas 8000 software version it needs to match your line. Integration. Connecting the module to your core unit, verifying assays and training staff. Service coverage. Platinum, Gold, Silver or Bronze, or per-visit support. Trade-in credit. The value of the analyzer or module you're retiring. Finance the c701 Finance or lease up to $2 million, with application-only approval up to $400,000. Start at $0 down with a low introductory payment. Get a fast credit decision and terms that fit your capital plan. Add shipping and other costs into the same payments. Send your current configuration and daily test count for a quote. REQUEST A QUOTE cobas c701 vs c702, and other options The reagent manager is the only difference between the c701 and the c702. Choose the cobas c701 if you want 2,000 tests an hour and 70 reagent positions, and your staff can plan reagent loads around the run. Choose the cobas c702 if you want the reagent manager: it holds 10 more cassettes, decaps them automatically and loads them while the module runs, so no one stops work to change reagents. Choose the cobas c502 if your cobas 8000 needs 600 tests an hour rather than 2,000, or a module for whole-blood HbA1c and specialty tests. Choose the cobas pro c503 if you're moving to Roche's newer cobas pro platform. Why buy your refurbished cobas c701 from Diamond Diamond technician rebuilding an analyzer down to the frame beside finished refurbished analyzers High-volume wear, rebuilt out A c701 that ran a large core lab for years carries that wear in its probes, mixers, washer and photometer, and a used module rarely comes with a record of what was replaced. Diamond rebuilds every c701 to the frame, fits new probes, syringes, seals, tubing and reagent lines, and validates it with multi-level QC before it's crated. We are FDA registered and ISO 9001:2015 and ISO 13485:2016 certified in the US and the EU. Installed on your line and serviced afterward Our engineers connect the c701 to your core unit, verify your assays and train your staff. Every module is eligible for our field service plans, from Platinum with next-day response to per-visit support. Preventive maintenance plans keep the c701 on its recommended schedule at a fixed cost. Trade in what it replaces We may take your old analyzer or module in trade, handle the deinstall and decontamination, and apply its value to your c701. Ask for more information from your sales rep. REQUEST A QUOTE Roche cobas c701 FAQ Q: What is the throughput of the cobas c 701 module?A: Up to 2,000 photometric tests an hour. Q: How many reagent positions does the cobas c701 have?A: 70 reagent cassette positions, with RFID identification. Q: What's the difference between the cobas c701 and c702?A: The reagent manager is the only difference. The c702 adds 10 cassette positions in the reagent manager, decaps cassettes automatically and loads them during operation. Throughput and the rest of the module are the same. Q: Does the cobas c701 run electrolytes?A: No. The c701 is photometric only. Electrolytes run on the cobas 8000 ISE module beside it. Q: Can I add a refurbished c701 to my existing cobas 8000?A: Yes. Send us your current module lineup and software version, and we'll match a rebuilt c701 to your line and install it.

Down-To-Frame Refurbishment Process

Factory Refurbished
FDA ISO

Upgrading or Adding Equipment to your lab?

Save up to 70% with refurbished equipment from Abbott, Alfa Wasserman, Beckman, Biomerieux, Biotechnia, Hitachi, Horiba ABX, IL, J&J, Radiometer, Randox, Roche, Siemens, Stago, Sysmex, Thermo and Tosoh.

Diamond is the only USA FDA registered, ISO Certified and Down-To-Frame® refurbisher of Chemistry, Immunology, Hematology, Coagulation and Blood Gas equipment. Inquire today for pricing and Details.

Every analyzer undergoes a systemized, rigorous and unique Down-To-Frame® Refurbishment process to rebuild each analyzer to its original specification and intended use.

Disassembly
Aesthetics
Refurbishment
Diagnostics
Validation
Final Packing
Disassembly & Decommission
  • System decommissioned from laboratory and decontaminated
  • Preliminary inspection of functionality
  • System disassembled Down-To-Frame®
Aesthetic Restoration
  • All outer covers, chassis and internal surfaces stripped, sand blasted and prepared for painting
  • All prepared surfaces primed and painted with 3 part compound, color matched automotive quality paint
  • All original logos and signage are replaced in original appearance
Refurbishment & Reassembly
  • All mechanical, pneumatic, electronic assemblies disassembled, cleaned, restored, verified and reassembled, replaced where needed
  • Disposable components replaced with new components
  • New components include: tubing, fittings, syringes, seals, check valves, probes, reagent lines, waste assemblies and similar items
  • System completely reassembled into its original condition in accordance to protocol and established specifications
Diagnostics & Troubleshooting
  • Assembly Functions & System errors assessed, troubleshooting and repair conducted
  • Full system diagnostic testing conducted
  • System successfully calibrated with certified calibrator materials to ensure proper functionality
Performance Validation
  • Rigorous Multi-Level Quality Control testing conducted on established parameters using certified control material
  • Specific parameter testing available upon request
  • System checked for power stability, software revisions and other upgrades
Final Packing
  • Required peripherals for operation refurbished or provided new as needed
  • System properly flushed, drained, protected and prepared for storage
  • System professionally crated with heat-treated and non-coniferous wood for international transit

Performance & Configuration
Assays

57 Total Assays Tested

*************(****), ******(****), **************(******), ********(******), *******(***), **************(*****), ************(*****), *********(****), ***************(******), ********(*****), **********(****), ************(*****), ************(***), ******(******), ***************(***), *********(****), ***********(****), ********(****), ***************(******), ***************(*****), **************(*****), **************(***), ********(***), *************(****), ***********(****), **************(******), **************(******), **********(******), **********(******), **************(****), **************(****), **********(****), **********(****), *******(****), *********(***), *************(****), ************(******), **************(***), ********(***), *************(***), *************(****), *******(*****), **********(****), ***********(***), ********(******), ************(******), *************(******), *********(******), ***************(****), ***********(****), **************(****), **********(******), ******(***), ********(***), ***********(***), *********(***), *******(******)

Technical Specifications
Manufacturer:Roche Diagnostics (Hoffmann)
Series:Cobas 8000
CLIA Complexity:Moderate
Sample Types:CSF, Plasma, Urine, Serum, Hemolysate
Number of Assays:57
Maximum Throughput:2000 tests/hour
Sample Cycle Time:2 (sec)
Sample Size Min:1.5 μL
Direct Sample (STAT):Yes
Auto Sample Handling:Yes
Sample Input Type:
Sample Cup
Sample Tube
Reagent Type:Liquid
Reagent System:Closed
Reagent Capacity:70
On-Board Refrigeration:Yes
Configuration:Floor Model
Height:134 cm (53 in)
Width:150 cm (59 in)
Depth:114 cm (45 in)
Weight:680 kg (1496 lb)
  
Unit #2Core Unit
Height:107 cm (42 in)
Width:102 cm (40 in)
Depth:114 cm (45 in)
Weight:200 kg (440 lb)
Water Requirement:Yes
Water OnBoard Supply:No
Water Consumption:50 (L/hour)
Power Supply:220V
Point Of Care:No

All units sold by Diamond Diagnostics or units qualified by Diamond Diagnostics are eligible for Field Service coverage. Service plans are the best way to maximize your instrument investment and avoid the high costs associated with instrument failure. Our plans are designed to support optimum instrument performance, ensure reproducible results and minimize down-time. Our service plans provide a timely response from our dedicated engineers who are certified on an ongoing basis to ensure top-notch results, even in the most complex laboratory environments.

. Service OptionsPlatinumGoldSilverBronzeLaborLaborPer DiemTravelTravelPer VisitService PartsService PartsIncident TrackingIncident TrackingResponse TimeResponse TimeNext DayNext Business Day2 Business Days*First AvailablePhone SupportPhone SupportMon-Sun 0-24Mon-Sun 0-24Remote SupportRemote SupportHoliday SupportHoliday SupportPreventive MaintenancePrev Maintenance*Peripheral SupportPeripheral SupportComplimentary LoanerCompl LoanerRelocationRelocationRecommissionRecommissionDecommisionDecommisionDecontaminationDecontaminationTrainingTrainingAssay ProgrammingAssay ProgrammingIQ/OQ ValidationIQ/OQ Validation

: Included

: Chargeable

: None

* Contact for more details

Preventive Maintenance
Preventive Maintenance

For the laboratory looking to manage manufacture recommended preventative maintenance (PM) schedules for instrumentation at a fixed cost. The PM Service Plan will increase the reliability and reduce the risk and costs of unplanned maintenance and equipment downtime. Our plans are scheduled and planned around your specific instrument and operational needs.


Depot Service, Type 1
Depot Repair Per Diem

For the laboratory looking to maximize the life of their instrumentation while effectively managing repair costs. The Depot Repair is a per diem plan designed for any size instrument needing major repair, complete rebuild or recycling.


Depot Service, Type 2
Annual Depot Repair

For the laboratory looking to maximize the life of their instrumentation while effectively managing repair costs. Annual Depot Repair is an annual based plan designed for small to mid-sized instruments needing maintenance or repairs and can be easily shipped by your local carrier to our Depot Service Facility in Holliston, MA.


Phone Support
Phone Support

For the laboratory employing qualified service professionals, the Virtual Plan may be a suitable choice to replace or supplement Field Services. The Virtual plan offers its customers support by email and telephone, within business hours with communication directly with Clinical Engineering staff specialized in the model of instrumentation that the laboratory is utilizing. The Virtual Plan is annual.


Click here to learn more.

The names and logos of manufacturers, their instruments, and their products referred to herein may be protected by trademark or other law, and are used herein solely for purpose of reference. Products are available for international distribution only unless otherwise indicated. Diamond Diagnostics expressly disclaims any affiliation with products it does not manufacture, as well as sponsorship by other manufacturers. For current regulatory status on products within this website, please contact your sales representative. Prices and Information shown are for reference only and may change without notice. SmartLyte®, ProLyte®, CareLyte®, and Down-To-Frame® Refurbishing are Registered Trademarks of Diamond Diagnostics®. No mobile information will be shared with third parties/affiliates for marketing/promotional purposes. All the above categories exclude text messaging originator opt-in data and consent; this information will not be shared with any third parties.