The Abbott Architect ci4100 Chemistry Analyzer, provided by Abbott Diagnostics
Equipment Support
Service Options
Consumables
Quality Controls
Service Parts
Package Size: EA
Refurbished Abbott Architect ci4100 Chemistry and Immunoassay Analyzer
An Architect c4000 chemistry analyzer and an i1000SR immunoassay analyzer joined into one Architect ci4100, rebuilt Down-To-Frame® to original specification. Save up to 70% vs new, starting with $0 down.
The Abbott Architect ci4100 runs photometric, turbidimetric and ICT electrolyte chemistry alongside chemiluminescent immunoassays, at up to 900 tests an hour with 180 samples loaded at once. One System Control Center runs both analyzers. Buy it refurbished from Diamond and you pay up to 70% less than a new system costs.
check_circlePay up to 70% less than you would for a new Architect ci4100.
check_circleRun up to 800 chemistry and 100 immunoassay tests an hour, with up to 115 refrigerated reagent positions plus ICT for sodium, potassium and chloride.
check_circleLoad 180 samples, with 35 priority positions held for STAT work.
check_circlePair the c4000 or i1000SR you already own with a refurbished partner to complete your ci4100.
check_circleFinance up to $2 million with $0 down, and trade in the analyzers you're consolidating.
check_circleGet both analyzers rebuilt Down-To-Frame® by an FDA-registered, ISO 13485:2016 certified refurbisher, then installed, verified and serviced by our own engineers.
How the Abbott Architect ci4100 runs chemistry and immunoassay together
The ci4100 joins an Architect c4000 and an Architect i1000SR under one System Control Center, so your techs run both from one screen. Abbott uses identical technology, reagents and assay protocols across the Architect family, so a ci4100 reports results equivalent to the larger Architect systems in your network.
The chemistry side
scienceRun up to 800 photometric, turbidimetric and ICT electrolyte tests an hour from up to 90 refrigerated reagent positions.
memoryMeasure sodium, potassium and chloride together on the Integrated Chip Technology module.
flagMeasure hemolysis, icterus and lipemia indices on chemistry samples, and let the analyzer dilute out-of-range samples automatically.
swap_horizRun alternative reagents on certain chemistry tests where your methods allow.
The immunoassay side
biotechRun up to 100 chemiluminescent microparticle immunoassay (CMIA) tests an hour with Abbott's CHEMIFLEX detection.
calendar_monthKeep 25 refrigerated reagent positions loaded with liquid, ready-to-use reagents that stay stable onboard for 14 to 30 days.
scienceRun thyroid, fertility, cardiac and infectious disease assays from Abbott's Architect immunoassay menu.
water_dropTest serum, plasma, whole blood and urine from 10 to 150 µL of sample, 62 µL on average.
Across the whole system
priority_highLoad 180 samples on the Robotic Sample Handler, with 35 priority positions held for STAT work.
biotechUse primary tubes 72 to 102 mm tall and 9.6 to 16.1 mm wide, or sample cups with a 50 µL dead volume.
flagCatch clots and bubbles at aspiration on both analyzers, and hold sample carryover at 0.1 ppm or less.
lanSend results to your LIS over a bidirectional RS-232 interface with host query, and keep 50,000 results onboard.
Ask for the list of chemistry and immunoassay tests run on the ci4100 we have in stock, and check it against your menu.
Architect ci4100 throughput compared with the ci8200 and Alinity ci
The ci4100 runs up to 900 tests an hour, 800 chemistry and 100 immunoassay. The Architect ci8200 runs up to 1,400, and the Alinity ci up to 1,550. The ci4100 needs about 27.5 sq ft of floor, close to the Alinity ci's 25 sq ft and about 36% less than a ci8200.
join_innerChoose the ci4100 when your chemistry volume fits within 800 tests an hour and your immunoassay volume within 100, and you want both on one system.
view_weekChoose the ci8200 when you need up to 1,200 chemistry and 200 immunoassay tests an hour and have room for a system 127 inches wide.
upgradeChoose the Alinity ci when you want Abbott's current platform, up to 1,550 tests an hour, and the option to add modules later.
On the chemistry side, each sodium, potassium and chloride result from the ICT module counts as a test, so your real hourly output depends on how much of your menu is electrolytes.
SpecArchitect ci4100Architect ci8200Alinity ci
Analyzers joinedc4000 and i1000SRc8000 and i2000SRAlinity c and Alinity iMaximum throughputUp to 900 tests/hour (800 chemistry, 100 immunoassay)Up to 1,400 tests/hour (1,200 chemistry, 200 immunoassay)Up to 1,550 tests/hour (1,350 chemistry, 200 immunoassay)Sample capacity180 (35 priority positions)365300Refrigerated reagent positionsUp to 115, plus ICTUp to 146, plus ICT117, plus ICTH x W x D49 x 111 x 36 in (125.1 x 281.2 x 90.7 cm)48 x 127 x 49 in (121.9 x 322.6 x 124.5 cm)53 x 78 x 46 in (134 x 199 x 117 cm)Footprint27.5 sq ft (2.55 m²)43.2 sq ft (4.02 m²)25.1 sq ft (2.33 m²)Weight1,677 lb (760.7 kg)2,447 lb (1,109.9 kg)2,557 lb (1,160 kg)
Buy a complete ci4100 or finish the one you've started
Buy the whole system from us, or build it around the analyzer you already own.
join_innerComplete ci4100. We supply both analyzers and the System Control Center, rebuilt and installed together.
add_circleYour c4000 plus a refurbished i1000SR. Add immunoassay to the chemistry analyzer your staff already run.
scienceYour i1000SR plus a refurbished c4000. Bring chemistry and electrolytes onto the immunoassay analyzer you own.
crop_squareOne side only. If you need just chemistry or just immunoassay, we sell the either on their own.
trending_upRoom to step up. When your volume outgrows a ci4100, the ci8200 takes the same reagent cartridges and sample carriers and runs up to 1,400 tests an hour.
view_weekConfigurationArchitect ci4100
Up to (tests/hour)900
Sample capacity180
Refrigerated reagent positions115, plus ICT
H x W x D49 x 111 x 36 in (125.1 x 281.2 x 90.7 cm)
Weight1,677 lb (760.7 kg)
view_weekConfigurationArchitect c4000 alone
Up to (tests/hour)800
Sample capacity100
Refrigerated reagent positions90, plus ICT
H x W x D49 x 63 x 36 in (125.1 x 160 x 90.7 cm)
Weight1,132 lb (513.5 kg)
view_weekConfigurationArchitect i1000SR alone
Up to (tests/hour)100
Sample capacity65
Refrigerated reagent positions25
H x W x D49 x 59 x 30 in (124.5 x 149.9 x 76.2 cm)
Weight636 lb (288 kg)
Tell us which Architect analyzers you run now and your daily chemistry and immunoassay volumes, and we'll recommend the setup.
Plan floor space, power and water for your Architect ci4100
The joined ci4100 is 125 cm (49 in) tall, 281 cm (111 in) wide and 91 cm (36 in) deep, about 27.5 sq ft of floor, and 761 kg (1,677 lb).
electrical_servicesRun the chemistry side on AC 180 to 264 V, 47 to 63 Hz, from a 20 A circuit.
boltRun the immunoassay side on AC 110 to 120 V or 200 to 240 V, 50 or 60 Hz. It adjusts to either.
water_dropPlumb deionized water for chemistry, about 15 L (4.0 gal) an hour in normal operation and up to 25 L (6.6 gal) an hour at peak. The immunoassay uses purified water to dilute its buffer concentrate.
thermostatSize your HVAC for about 3,050 BTU an hour from the chemistry analyzer and 2,400 BTU an hour from the immunoassay in running mode, plus up to 389 BTU an hour from the System Control Center.
lanConnect to your LIS over a bidirectional RS-232 serial interface with host query.
Requirementc4000 chemistry sidei1000SR immunoassay side
PowerAC 180 to 264 V, 47 to 63 Hz, 20 AAC 110 to 120 V or 200 to 240 V, ±10%, 50 or 60 Hz, self-adjustingWaterDeionized, 15 L/hr (4.0 gal/hr) normal, 25 L/hr (6.6 gal/hr) maxPurified water to dilute buffer concentrateHeat output, running mode3,050 BTU/hr2,400 BTU/hrHost interfaceBidirectional RS-232 serial, host query optionBidirectional RS-232 serial, host query option
Send us your room layout and utilities, and we'll check them against the ci4100 before you commit.
Which labs buy a refurbished Abbott Architect ci4100?
Abbott built the ci4100 to give lower-volume labs the same Architect chemistry and immunoassay that larger labs run.
local_hospitalSmaller hospital labs. Run chemistry, electrolytes and immunoassay on one system, with 35 priority positions for ED and inpatient STAT samples.
sync_altLabs consolidating two older analyzers. Replace a separate chemistry analyzer and immunoassay analyzer with one system run from one screen.
content_copyHospital networks on Architect. Put a ci4100 in a smaller site and report results equivalent to the c8000 or ci8200 in your core lab.
scienceLabs running cardiac markers for the ED. A five-year review of QC data found stable high-sensitivity troponin I performance on Architect ci4100 analyzers.
verified_userLabs shopping for a used ci4100. Compare any used system with one rebuilt to the frame, installed by our engineers and eligible for our field service plans.
Abbott Architect ci4100 price: new, used or refurbished
Abbott sells new ci4100 systems through contracts, often tied to a reagent agreement that spreads the instrument cost across your per-test pricing. We price each refurbished ci4100 individually, because the chemistry and immunoassay components each carry their own year of manufacture. Whichever system fits your lab, you pay up to 70% less than new and own it outright.
A ci4100 is two analyzers, each with its own history. Before you set a used system's price against a refurbished one, count what it will cost to get both analyzers reporting patient results.
Questions to ask before you buy a used ci4100
What year was each analyzer manufactured?
Were both analyzers decontaminated, and can the seller document it?
Which wear parts were replaced on each analyzer, and when?
Do both sides pass calibration and multi-level QC today, and can you see the results?
What software version does the system run?
How many determinations are left on the c4000's ICT module?
Who installs both analyzers, programs your assays and verifies them?
Who services the system once it's running, and what does that cost?
Every refurbished ci4100 from Diamond is decontaminated, rebuilt with new wear parts on both analyzers, calibrated and QC-validated before it leaves our facility. Our engineers then install it and verify your assays on site.
What sets the price of your ci4100
The year of manufacture.
Whether you need the complete system or one analyzer to pair with yours.
Installation, assay programming and verification for chemistry and immunoassay.
Operator training.
The service plan you choose.
Freight and rigging for two analyzers.
The trade-in value of the analyzers you're retiring.
Why buy a refurbished ci4100 instead of new?
paymentsA smaller capital request. Cut the cost of a two-analyzer system by up to 70%.
add_circleOnly the analyzer you need. Complete the ci4100 around the components you already own.
keyOwnership. You own the system outright rather than paying for it through reagent pricing, and you decide who services it.
scienceResults that match your Architect fleet. A refurbished ci4100 runs the same Abbott reagents and assay protocols as a new one, and we supply the reagents and consumables.
recyclingLess waste. Rebuilding two analyzers keeps them working and out of landfill, and uses less energy and raw material than manufacturing new ones.
Get your ci4100 quote
Tell us which Architect analyzers you already own, your daily chemistry and immunoassay volumes and when you need the system running, and we'll quote the configurations that fit. Ask for the quote as a monthly payment too, starting at $0 down with low introductory payments, so you can compare it with a used system or a reagent agreement.
Why buy a refurbished Abbott Architect ci4100 from Diamond Diagnostics?
Our own engineers rebuild both analyzers, install the joined system in your lab and come back to service it.
build
Two analyzers rebuilt Down-To-Frame®
We decontaminate both pieces, take each one down to the frame, and restore or replace every assembly, from the c4000's reaction carousel and ICT unit to the i1000SR's process path and chemiluminescence optics. Both analyzers get new probes, syringes, seals, tubing and reagent lines. We calibrate each one with certified calibrators, validate both with multi-level QC and, on request, run your own chemistry and immunoassay tests.
verified_user
FDA-registered and certified to ISO 13485:2016
We hold FDA registration as a refurbisher, and our US and EU facilities hold ISO 9001:2015 and ISO 13485:2016 certification. ISO 13485 sets the quality management requirements for medical device makers, and external auditors check our work against both standards.
engineering
Installed and verified as one system
Our engineers set up both analyzers, connect them to the System Control Center, program your chemistry and immunoassay menus and verify them before you report patient results. On-site operator training is available after installation, covering the instrument, your menu, adding parameters, preventive maintenance and first-line troubleshooting, with an hour for your team's questions.
account_balance
$0-down financing for your Abbott Architect ci4100 analyzer
Spread purchases of up to $2 million across a lease or a loan.
Apply for up to $400,000 with nothing more than a credit application.
Start with $0 down and low introductory payments.
Hear back fast on credit, and choose from a broad range of terms.
Fold freight and other purchase costs into the financing.
swap_horiz
Trade in the analyzers your ci4100 replaces
Retiring separate chemistry and immunoassay analyzers? We'll buy them and credit their value toward the ci4100. We deinstall and decontaminate them, pick them up and pay the freight, so they don't sit in storage or end up on a disposal invoice.
handymanField service from Diamond engineers
Every ci4100 we sell is eligible for our field service plans, and so is a ci4100 you bought elsewhere once we qualify it.
Pick a plan from Platinum, with next-day response and round-the-clock phone support, down to Bronze, scheduled at first availability.
Keep both analyzers on the manufacturer's preventive maintenance schedule at a fixed cost, timed around your lab's hours.
Reach clinical engineers who specialize in your model by phone or email.
Add assay programming, relocation, decommissioning and decontamination when you need them.
Compare service plans
Frequently asked questions about the Abbott Architect ci4100
How many tests per hour does the Abbott Architect ci4100 run?Up to 900 tests an hour, with up to 800 on the c4000 chemistry side and up to 100 on the i1000SR immunoassay side.
How much does an Abbott Architect ci4100 cost?Abbott prices new systems by contract, often inside a reagent agreement. A refurbished ci4100 from Diamond costs up to 70% less than new. We price each system individually, based on the year of manufacture of both analyzers, whether you need one analyzer or both, and the services you add.
Should I buy a used or a refurbished Architect ci4100?A used ci4100 is two analyzers with two service histories, so ask the seller about each one's year of manufacture, decontamination, replaced wear parts and current QC results. A refurbished ci4100 from Diamond is rebuilt to the frame on both sides, calibrated and QC-validated, then installed and verified by our engineers and eligible for our field service plans.
What's the difference between the Architect ci4100 and ci8200?The ci4100 joins a c4000 and an i1000SR and runs up to 900 tests an hour from 180 samples. The ci8200 joins a c8000 and an i2000SR and runs up to 1,400 tests an hour from 365 samples, in a system 127 inches wide against the ci4100's 111. Both use the same Architect reagents and assay protocols.
Should I buy an Architect ci4100 or an Alinity ci?The Alinity ci is Abbott's current platform, running up to 1,550 tests an hour with the option to add modules. The ci4100 runs up to 900 and keeps your lab on Architect, with the reagents and training you already have.
I already own a c4000. Can you turn it into a ci4100?Yes. We pair a refurbished i1000SR with your c4000 and install them together as a ci4100. If you own an i1000SR, we add a refurbished c4000 instead.
What immunoassay tests run on the ci4100?The i1000SR runs thyroid, fertility, cardiac and infectious disease assays from Abbott's Architect immunoassay menu. Ask us for the list of tests run on the system in stock.
Can the ci4100 run non-Abbott reagents?On certain chemistry tests, yes, where your methods allow. Ask us which tests on your menu qualify.
What power and water does the ci4100 need?The c4000 runs on AC 180 to 264 V from a 20 A circuit, and the i1000SR runs on 110 to 120 V or 200 to 240 V. The c4000 uses about 15 L (4.0 gal) of deionized water an hour, and the i1000SR uses purified water to dilute its buffer.
What financing is available for a refurbished ci4100?Lease or finance up to $2 million with $0 down and low introductory payments. Up to $400,000 needs only a credit application, and freight can go into the financed amount.
Will you take our current analyzers in trade?Yes. We buy the analyzers you're retiring, credit their value toward your ci4100, and handle deinstallation, decontamination, pickup and freight.
Do you install the ci4100 and train our staff?Yes. Our engineers install both analyzers, program and verify your chemistry and immunoassay tests, and offer on-site operator training after installation.
Can you service a ci4100 we bought somewhere else?Yes. Once we qualify it, it's eligible for the same field service plans as the systems we sell.
Can I get Architect ci4100 reagents from Diamond?Yes. Reagents and consumables for both the c4000 and the i1000SR are available through Diamond Diagnostics.


Upgrading or Adding Equipment to your lab?
Save up to 70% with refurbished equipment from Abbott, Alfa Wasserman, Beckman, Biomerieux, Biotechnia, Hitachi, Horiba ABX, IL, J&J, Radiometer, Randox, Roche, Siemens, Stago, Sysmex, Thermo and Tosoh.
Diamond is the only USA FDA registered, ISO Certified and Down-To-Frame® refurbisher of Chemistry, Immunology, Hematology, Caogulation and Blood Gas equipment. Inquire today for pricing and Details.
Every analyzer undergoes a systemized, rigorous and unique Down-To-Frame® Refurbishment process to rebuild each analyzer to its original specification and intended use.
129 Total Assays Tested
**********(*****), ***************(***), ********(******), *******(******), *******(****), *********(******), *************(***), *******(****), ********(****), *************(*****), ************(***), ******(****), ************(*****), ************(*****), **********(***), **********(*****), ******(*****), *************(******), ********(******), *********(*****), ******(****), ***********(****), ********(******), **************(******), **********(******), *********(***), ***************(***), ***********(******), ***************(****), *********(*****), *************(****), ********(***), **********(***), *************(****), *************(*****), ***********(***), ********(*****), *******(***), *************(******), *************(***), ******(***), ***********(****), *************(*****), **********(*****), ***************(*****), ************(****), **********(*****), *********(****), ******(*****), *************(****), *******(******), *******(*****), ***********(****), ***************(******), ******(****), *********(***), *********(******), ************(******), *********(*****), ******(****), ***************(***), **********(***), ******(***), ************(*****), ***********(****), **********(*****), ************(***), *************(******), **********(****), *************(*****), ***************(***), *********(****), ********(****), ***********(***), ******(***), **************(****), *************(****), ******(*****), ***********(******), **********(*****), **********(*****), ***********(******), *************(*****), **************(***), **********(****), ******(******), *********(****), ******(*****), *************(****), **************(***), ***********(***), ***************(****), ************(****), **************(***), *******(****), *************(***), ***********(***), *********(*****), *********(***), ***********(******), *************(*****), **************(****), ******(****), *******(***), ******(*****), **********(***), ***************(*****), **************(******), ******(*****), ******(*****), **************(****), *************(***), *********(****), *************(*****), ********(****), ********(******), *******(****), ***************(*****), ********(******), **********(*****), ********(******), ***********(***), *************(*****), ***************(*****), *********(***), ******(***), *******(****), **********(******), ********(*****)
| Private Labeled by: | Toshiba Medical (now Canon Medical Systems) |
| Private Label Source Model: | TO-CI4100 |
| Series: | Architect |
| CLIA Complexity: | Moderate |
| Sample Types: | CSF, Plasma, Urine, Whole Blood, Serum |
| Number of Assays: | 129 |
| Maximum Throughput: | 900 tests/hour |
| Sample Size Min: | 1.5 μL |
| Direct Sample (STAT): | Yes |
| Auto Sample Handling: | No |
| Sample Input Type: | Sample Cup Sample Tube |
| Reagent Type: | Liquid |
| Reagent System: | Partial Open |
| Reagent Capacity: | 115 |
| On-Board Refrigeration: | Yes |
| Configuration: | Floor Model |
| Height: | 125 cm (49 in) |
| Width: | 160 cm (63 in) |
| Depth: | 91 cm (36 in) |
| Weight: | 514 kg (1130 lb) |
| Unit #2 | i1000SR |
| Height: | 125 cm (49 in) |
| Width: | 150 cm (59 in) |
| Depth: | 76 cm (30 in) |
| Weight: | 288 kg (634 lb) |
| Water Requirement: | Yes |
| Water OnBoard Supply: | No |
| Water Consumption: | 15 L/hour normal, 25 L/hour max (c4000); purified water for buffer dilution (i1000SR) (L/hour) |
| Power Supply: | 110V-220V |
| Point Of Care: | No |
All units sold by Diamond Diagnostics or units qualified by Diamond Diagnostics are eligible for Field Service coverage. Service plans are the best way to maximize your instrument investment and avoid the high costs associated with instrument failure. Our plans are designed to support optimum instrument performance, ensure reproducible results and minimize down-time. Our service plans provide a timely response from our dedicated engineers who are certified on an ongoing basis to ensure top-notch results, even in the most complex laboratory environments.
: Included
: Chargeable
: None
* Contact for more details

For the laboratory looking to manage manufacture recommended preventative maintenance (PM) schedules for instrumentation at a fixed cost. The PM Service Plan will increase the reliability and reduce the risk and costs of unplanned maintenance and equipment downtime. Our plans are scheduled and planned around your specific instrument and operational needs.

For the laboratory looking to maximize the life of their instrumentation while effectively managing repair costs. The Depot Repair is a per diem plan designed for any size instrument needing major repair, complete rebuild or recycling.

For the laboratory looking to maximize the life of their instrumentation while effectively managing repair costs. Annual Depot Repair is an annual based plan designed for small to mid-sized instruments needing maintenance or repairs and can be easily shipped by your local carrier to our Depot Service Facility in Holliston, MA.

For the laboratory employing qualified service professionals, the Virtual Plan may be a suitable choice to replace or supplement Field Services. The Virtual plan offers its customers support by email and telephone, within business hours with communication directly with Clinical Engineering staff specialized in the model of instrumentation that the laboratory is utilizing. The Virtual Plan is annual.
The names and logos of manufacturers, their instruments, and their products referred to herein may be protected by trademark or other law, and are used herein solely for purpose of reference. Products are available for international distribution only unless otherwise indicated. Diamond Diagnostics expressly disclaims any affiliation with products it does not manufacture, as well as sponsorship by other manufacturers. For current regulatory status on products within this website, please contact your sales representative. Prices and Information shown are for reference only and may change without notice. SmartLyte®, ProLyte®, CareLyte®, and Down-To-Frame® Refurbishing are Registered Trademarks of Diamond Diagnostics®. No mobile information will be shared with third parties/affiliates for marketing/promotional purposes. All the above categories exclude text messaging originator opt-in data and consent; this information will not be shared with any third parties.