Reagent Handling & Cold-Chain Basics for ABGElectrolyte Systems

In every hospital or laboratory, diagnostic decisions depend on trust. Physicians rely on lab results as a guide to make life-saving interventions.

Among the most critical of these diagnostics are arterial blood gas (ABG) and electrolyte tests. They are known to be fast, precise and indispensable in emergencies.

However, what ensures their reliability is not only the analyzer but the integrity of the reagents inside it. Reagents are the true foundation of ABG and electrolyte testing.

They are chemically complex and are designed to mimic physiological conditions with buffers, enzymes and electrolytes that are sensitive to time or temperature.

If handled incorrectly such as the reagent cold chain breaking or if the storage temperature for ABG conditions are ignored, calibrations can fail and patient outcomes may be placed at risk.

The good news however is that reagent handling is like science in itself, with clear manufacturer guidelines. Documentation emphasizes everything from cartridge stability to visible signs of degradation from shipping with ice packs, along with stability limits once reagents are placed on board.

By embedding these requirements into a lab’s daily practice, teams can protect their test accuracy, reduce waste and sustain confidence in the results that they deliver.

Why the Cold Chain Matters

The cold chain is the unbroken pathway of controlled storage and handling conditions that preserves reagents all the way from the factory to the analyzer.

For ABG and electrolyte reagents, this pathway usually involves refrigeration that’s typically between 2–8 °C or 2–10 °C. This is dependent on the product.

The inserts highlight just how sensitive stability can be. Many multi-level controls are stable for 36 months unopened under correct storage. Yet once opened, they can only remain viable for 60 seconds per vial.

Some reagent kits can remain stable until expiration when refrigerated. These are limited to 30 days once they are loaded in a refrigerated carousel within the analyzer.

These differences underscore the importance of maintaining conditions precisely as directed. A lapse of even a few hours outside the required range can undo months of preserved stability.

Shipping and Receiving: Protecting the First Step

Manufacturers transport reagents in insulated packaging. They are often shipped with ice packs to provide safety against environmental extremes.

While specific logistics may vary, the goal is universal. That is the protection of reagents until placement in a more controlled lab storage. Once the shipments arrive, labs move on to play the next critical role.

The receiving inspection reagents process ensures that no compromised reagent enters the workflow. Shipments should be opened immediately, packaging inspected and reagents checked for any visible defects. These can vary from cloudiness, precipitation or broken seals.

Caution is required as the reagents showing such signs have to be discarded since chemical integrity would no longer be guaranteed.

If there is any suspicion of temperature excursions, reagents should not be used. Labs are expected to isolate them and apply corrective action excursions procedures. This is done by either holding them for verification, running QC checks or requesting replacements.

Through receiving an inspections routine, labs can protect themselves from downstream errors that might otherwise only appear during patient testing.

Storage in the Laboratory

Once accepted, reagents must be stored strictly according to instructions. 

Across reagent and control inserts, the consistent guidance is by refrigeration at 2–8 °C or 2–10 °C. Inserts and manuals stress that freezing must be avoided as this can irreversibly damage buffers and electrolytes.

Operator manuals reinforce the importance of storage by stating that “storage temperature must be observed” to preserve shelf life and that all reagents carry a “Use By” date.

Importantly, once reagents are placed into analyzers, the stability time is shortened significantly. A reagent kit can be valid for 12 months when refrigerated but only 30 days in the analyzer carousel. Therefore, labs must also monitor storage closely while storing reagents correctly as well.

While documentation highlights temperature requirements, many labs implement weekly temperature logs or automated monitoring to ensure compliance.

If refrigerators fail or show excursions, the affected reagents have to be isolated until stability can be confirmed through QC or consultation with the supplier.

Cartridge Stability and Expiration Management

The concept of cartridge stability is central to ABG and electrolyte systems. 

Each reagent pack or cartridge has two lifespans.

Unopened shelf stability and in-use stability once installed. Both are detailed in inserts and must be respected to ensure reliable calibration and measurement.

Expiration management is another non-negotiable requirement.

All reagents are marked with expiration dates that cannot be exceeded. Even if reagents appear clear or intact, their performance cannot be guaranteed past that date.

To manage this, labs apply inventory rotation, FEFO (First Expire, First Out) which ensures that reagents with a shorter shelf life are consumed first. 

This minimizes waste and keeps testing aligned with stability claims.

Quality Control and Storage Conditions

The effect of reagent handling is often most visible during quality control. 

Inserts note that reagents showing signs of degradation must be discarded. In practice, compromised storage can appear as widening QC ranges, consistent bias or calibration drift.

The QC impact of storage links directly to handling practices.

If QC failures occur unexpectedly, reviewing reagent storage and monitoring logs is one of the first troubleshooting steps.

Replacing compromised reagents often resolves performance issues faster than investigating instrument hardware.

This connection underscores why reagent management is just as critical to quality assurance as analyzer maintenance.

Reagent Lot Changes

Lot changes are a natural part of reagent use, but they require careful handling. Documentation emphasises traceability through lot numbers and expiration dates.

When introducing a new lot, labs are expected to check performance consistency. This may involve running QC samples across both lots, along with comparing results and documenting the transition.

A structured reagent lot change process prevents undetected shifts from one lot to the next. 

By validating new lots before use, labs ensure continuity while preserving confidence in patient data for the long term.

Reducing Waste Through Forecasting

While manufacturer documentation centers on stability and storage, the financial impact of reagent management is clear. Expired or discarded reagents represent unnecessary costs.

Labs can minimize this through consumables forecasting, where ordering is based on projected workload and historical usage.

Combined with FEFO rotation, forecasting helps achieve waste reduction reagents. It prevents over-ordering that leads to expiration and under-ordering that risks shortages.

By aligning supply with demand, labs can balance reliability with efficiency.

Training and SOPs

Even the most detailed inserts depend on human action. That is why staff training reagents is essential. Clinical staff must be familiar with manufacturer requirements, understanding the ways on how to apply them consistently.

Written SOP template reagents provide the structure needed. These documents should outline receiving inspections, storage monitoring, corrective action excursions and more. SOPs not only standardize practices but also provide a record for audits and accreditations.

By combining training with SOPs, labs make reagents handling a disciplined, repeatable process.

Key Takeaways 

Reagent handling is often invisible in the daily workflow and yet it underpins every test result in ABG and electrolyte systems.

Protecting the reagent cold chain, following clear rules for cartridge stability, along with expiration management and more are not just technical requirements but commitments to patient safety.

From shipping with ice packs and receiving inspection reagents to carefully logging temperatures and validating each reagent lot change, every step safeguards reliability.

The QC impact of storage provides reminders that lapses are not forgiven as every small action in reagent handling has consequences for calibration and results.

Ultimately, the way labs manage reagents can reflect on its professionalism and dedication to accuracy.

By aligning with manufacturer documentation, embedding best practices like inventory rotation FEFO and consumables forecasting, labs can minimize errors, while controlling all around costs. Most importantly, they can deliver results that clinicians and patients can trust.

Through careful handling, reagents can be more than consumables.

The names and logos of manufacturers, their instruments, and their products referred to herein may be protected by trademark or other law, and are used herein solely for purpose of reference. Products are available for international distribution only unless otherwise indicated. Diamond Diagnostics expressly disclaims any affiliation with products it does not manufacture, as well as sponsorship by other manufacturers. For current regulatory status on products within this website, please contact your sales representative. Prices and Information shown are for reference only and may change without notice. SmartLyte®, ProLyte®, CareLyte®, and Down-To-Frame® Refurbishing are Registered Trademarks of Diamond Diagnostics®. No mobile information will be shared with third parties/affiliates for marketing/promotional purposes. All the above categories exclude text messaging originator opt-in data and consent; this information will not be shared with any third parties.